01Construction Services · Structural

New Construction & Custom Structural Design

SunSmart Engineering provides sealed structural engineering for new construction, custom structures and retrofits. Our clients are builders, contractors and developers in Florida, across the U.S. and in the Caribbean. You send the plans, loads and site details. You get stamped drawings and calculations built for the wind, soil and code conditions at the address, ready for plan review.

01

Areas of expertise.

01
Custom Structural Design

Structures that do not fit a standard table: long spans, unusual geometry, mixed materials and one-off frames. We calculate them for the actual site loads.

02
New Construction Plans

Foundation, framing and lateral design for homes and commercial buildings, matched to the architectural set and the local code.

03
Material Optimization

Members and connections sized to the load instead of rounded up by habit, so the design carries what it must and no more.

04
Code Compliance and Permitting

Calculations and sealed sheets organized the way a plan reviewer reads them, with responses ready for review comments.

02

What is in the package.

Structural engineering drawings and calculations for a new construction project

Every structural package is built to be read by a plan reviewer and followed by a crew in the field. The exact contents depend on the project, and we confirm them with you before we start.

Structural calculations

Gravity, wind and lateral checks for the members and connections, with the design criteria stated up front.

Foundation and framing plans

Footings, slabs, columns, beams, headers, trusses or rafters, and the details a framer or fabricator needs.

Connection and anchorage details

How each load reaches the next member and the ground: fasteners, embedment, hold-downs and uplift ties.

Wind load analysis

Design pressures per ASCE 7 for the address, exposure category, building height and risk category.

Signed and sealed drawings

A permit-ready set sealed for the jurisdiction. Our Florida engineering firm authorization is COA35170.

Answers to review comments

When the reviewer comments on our sheets, we respond with revised details or added calculations.

03

Who this is for.

01
Builders and general contractors

New homes, additions and commercial buildouts that need a sealed structural set to get through permitting.

02
Solar and battery contractors

Roof and ground-mount projects where the building department wants the existing structure checked for the new load. See our solar PV and storage services.

03
Pool, enclosure and aluminum contractors

Custom frames, canopies, equipment platforms and structures that fall outside a manufacturer's tested limits.

04
Roofing and exterior contractors

Roof framing, re-roof attachment questions, awnings, railings and other exterior structures that need a sealed detail.

04

How it works.

The process is short, and most of the work on your side is sending complete information at the start.

01
Send the project package

Site address, architectural or sketch plans, any survey or soil report, the use of the structure, and product data if a manufactured product is involved.

02
We confirm scope and design criteria

We set the wind speed, exposure and risk category, soil assumptions and code edition for the address, and tell you what else we need.

03
Engineering

We size the members and connections, check the load path from roof to foundation, and prepare the calculations and drawings.

04
Seal and deliver

You receive the sealed drawing set and calculations ready to submit with your permit application.

05
Support through review

If the building department comments on our sheets, we answer with revised details or added calculations.

05

Codes and approvals involved.

Structural plans are reviewed against the code edition and wind criteria in force where the permit is filed. These are the references that come up most.

Florida Building Code editions

The 8th Edition (2023), with the 2020 NEC, applies through December 30, 2026. The 9th Edition (2026), with the 2023 NEC, is scheduled to take effect December 31, 2026. Check which edition your permit application falls under.

ASCE 7 wind loads

Design wind speed, exposure category and risk category drive the pressures on the roof, walls and attachments. We set them for the exact address.

High-Velocity Hurricane Zone

The HVHZ is Miami-Dade and Broward. It has stricter wind provisions (Section 1620) and roofing rules (Chapter 15), and it requires Miami-Dade NOA product approvals for many products.

Product approvals

Manufactured products such as windows, doors, roof coverings and aluminum assemblies are accepted within their tested limits. Outside those limits, a site-specific engineering evaluation fills the gap. See our windows, doors, roofing and exteriors service.

Authority having jurisdiction

The local building department makes the final call on what it accepts. Some jurisdictions have their own forms, wind maps or letter requirements, and we design to them when you tell us about them.

06

Problems we solve or prevent.

01
Permit rejected for an incomplete load path

Reviewers want to see how each load travels to the foundation. A clear set of details and calculations answers that before they ask.

02
Plans change after the engineering is done

A moved opening or a longer span changes the framing. Send revisions early so the sealed set matches what the crew will build.

03
Existing structure cannot carry the new load

Solar arrays, rooftop equipment and added canopies add weight and uplift. An evaluation up front avoids discovering that at inspection.

04
A product is used outside its approval

When an opening or span is larger than the tested condition, a sealed evaluation can document a compliant alternative.

+FAQ

Structural engineering questions.

Have a different question?

The engineer sizes the members and connections that carry the building's loads down to the ground, then documents them on sealed drawings and calculations. That covers gravity loads, wind and, where it applies, snow and seismic. The building department reviews that package before it issues the permit.

Yes. Send the current architectural set, because a change to openings, spans or roof shape changes the framing and the loads. We design the structure to match the plans you send and flag anything that does not work as drawn.

Yes. Custom and one-off structures are what this service is for. We calculate the members, connections and foundation for the site conditions instead of leaning on a generic table, and we show the work so the plan reviewer can follow it.

Yes. Rooftop equipment, solar arrays, new canopies and added floors all put new loads on a structure that was designed for something else. We evaluate the existing framing and connections, then issue a sealed letter or a retrofit detail.

Send the site address, the architectural or sketch plans, any survey or soil report, and a note on the use of the building or structure. If a manufacturer's product is part of the design, include its product data. We will tell you what else the scope needs.

In Florida, the Florida Building Code, 8th Edition (2023) applies through December 30, 2026, and the 9th Edition (2026) is scheduled to take effect December 31, 2026. Check which edition your permit application falls under. Wind loads follow ASCE 7 for the address, exposure and risk category. Outside Florida, we design to the code your jurisdiction has adopted.

Tell us at intake if the site is in Miami-Dade or Broward. The HVHZ has stricter wind and roofing provisions and often requires Miami-Dade NOA product approvals, and that changes both the design and what the reviewer looks for.

Yes. We serve contractors across the U.S. and in the Caribbean. For a job outside Florida, send the governing code and the design wind speed if the local building authority has given you one.

07

Get Started

Send the site address, the plans or a sketch, and a note on what you are building. We will confirm the scope and tell you what else we need. You can also call 866-SUN-8655 or email solutions@sunsmartengineering.com.

08

Structural guides.

Two of our guides go deeper on the structural questions we get most from solar and exterior contractors.